EasyManuals Logo
Home>Pyronix>Security System>ENFORCER V11

Pyronix ENFORCER V11 Installation Guide

Pyronix ENFORCER V11
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
ENFORCER V11 INSTALLATION GUIDE
CONNECTING EXPANSION MODULES
Connecting a wired zone expander
Up to 4 wired zone expanders can be connected to the Enforcer.
- + D3 D4
---485 BUS---
0V +12V
AUX
ALARM TAMPER
EOL INPUT 1 COM
ALARM TAMPER
EOL INPUT 2 COM
ALARM TAMPER
EOL INPUT 3 COM
ALARM TAMPER
EOL INPUT 4 COM
ALARM TAMPER
EOL INPUT 5 COM
ALARM TAMPER
EOL INPUT 6 COM
ALARM TAMPER
EOL INPUT 7 COM
ALARM TAMPER
EOL INPUT 8 COM
POWER OK FAULT
HOLD OFF
1
2
4
8
16
32
RESET
PGM STB BELL Z33 COM +12V Z34D1- D2+ D3 D4
Please note: The above shows the I/O board connected to a EURO-ZEM8, a EURO-ZEM8+ is connected in
the same way. If using a EURO-ZEM8+PSU, the D2+ MUST NOT be connected.
ZEM address 0
Zones 35-42
ZEM address 1
Zones 43-50
ZEM address 2
Zones 51-58
ZEM Address 3
Zones 59-66
Connecting a wireless zone expander
1 wireless zone expander can be connected to the Enforcer however, this expander can take the place of 4
addresses potentially expanding the system by 32 wireless peripherals.
IMPORTANT NOTE: The wireless ZEM must be addressed as ‘Device B’ via the jumper headers.
PGM STB BELL Z33 COM +12V Z34D1- D2+ D3 D4
- + D3 D4 T T
The wireless ZEM allows a maximum 32 wireless zones to be learnt. These 32 zones are programmed as 4 dierent
ZEMs (addresses), and each having 8 wireless zones assigned.
Example
Wired and wireless zone expanders can be installed together on a system and, as long as they are addressed
uniquely, they will work alongside each other. For instance, if you wish to use 24 wireless zones and 8 wired zones,
you can program the wireless ZEM as ZEM addresses 00, 01 and 02 in the menu item
instAll ZeM and learn 24
zones to the system using the WiReless deviCe ContRol menu. Then address a wired ZEM as ZEM 03.

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals