ENFORCER V11 INSTALLATION GUIDE
Wireless ZEM header addressing
WIRELESS ZEM ADDRESS DEVICE A
03
DEVICE B
47
DEVICE C
811
ZEM32-WE
ZEM address 00 OFF ON OFF
ZEM address 01 OFF ON OFF
ZEM address 02 OFF ON OFF
ZEM address 03 OFF ON OFF
Wireless ZEM zone mapping
WIRELESS ZEM ADDRESS ZONES
ZEM32-WE
ZEM address 00 35-42
ZEM address 01 43-50
ZEM address 02 51-58
ZEM address 03 59-66
Please note: Wireless zones 35-66 can take upto 5 minutes to become active when armed.
Connecting an output expander
1 remote output expander can be connected to the Enforcer. The output expander allows 16 additional outputs.
PGM STB BELL Z33 COM +12V Z34D1- D2+ D3 D4
D1- D2+ D3 D4 D1- D2+ D3 D4
Please note: The above shows the I/O board connected to a EURO-OEM8R8T. If the expander is a EURO-
OEM16R+PSU, the D2+ terminal must not be connected to the I/O board.