10
Example:
Set panel (error tone will be heard).
Unset panel (alarm LED will be flashing).
View log to see which zones are faulty
and investigate fault(s) if possible.
Set panel,
then If no error tone heard, exit via normal route.
or If error tone heard:
Enter Fault tone will stop and Day LED will flash.
then Enter number(s) of zones to be omitted (1 to 6 ) Max of 5 zones.
Enter Entry / Exit timer will start again. Exit tone will continue.
then Exit building by normal route.
N.B If an Entry / Exit zone has to be omitted and your alarm system includes Walk-
through or Access zones, then the panel cannot be unset without first activating the
alarm. If a zone has been omitted because a fault persists then call engineer.
8 MASTER USER FACILITIES
The Master User has access to all the Limited User facilities as well as those listed
below.
**The Paragon Plus control panel has to be in day mode after resetting with the Master
code for these additional features to be accessed.**
1) Resetting alarm LED after an Activation
To clear flashing Alarm LED
Enter Master User (Factory set as 1234)
or Limited User (Factory set as 5678)
2) Changing Limited User Code
Enter
then Master User code - 2 Bleeps (Factory set as 1234)
then New Limited user code - 2 Bleeps
then New Limited user code again - 2 Bleeps
The day led will flash when this function is entered and an acknowledge tone will be
sounded after each code has been entered. If an incorrect key is entered an error
tone will be given and the function ended.
3) Changing Master Code
Enter
then Master User code, - 2 Bleeps (Factory set as 1234)
then New Master User code, - 2 Bleeps
then New Master User code. - 2 Bleeps
Errors tones as in 2) above.
4) System Test Mode
Enter
This function performs a number of tests which are listed below.
The next test is selected by pressing any numeric key.
To exit test mode press the Shift key again.
Test 1) All LEDs are switched on except the fault LED.
2) The strobe is switched on.
3) The bell is switched on
4) The internal sounder is switched on
5) Walk Test Mode
Enter
When the walk test mode is enabled the chime LED will flash. If the panel is then full
set or part set each active zone will cause a chime when triggered. This enables all
the zone configurations to be walk tested individually. The walk test mode is cleared
when the panel is unset.
11
RDOC147Fissue3