4 FUNCTIONAL DESCRIPTION
Operating Modes
Day Mode
This is the state of the panel when unset (not armed). Fire, Personal Attack and
Tamper inputs, however, remain active 24 hours a day. (These are referred to as 24
hour zones). Day mode is identified by the green Day LED on the front of the panel.
Set Modes
When the panel is set (armed) an activation of any Access, Immediate or 24 hour zone
will cause an alarm condition. When an alarm is generated the internal and external
sounders will operate for the length of time programmed and the tone of the internal
sounder will be two notes repeated rapidly. The strobe lamp will also be activated and
will continue to operate until the panel is reset.
Fullset / Partset
At the time of setting the control panel, any one of four set modes can be selected.
This allows part of a building to be monitored whilst another part is occupied. For
example, the ground floor of a house could be armed whilst the occupants are asleep
upstairs. Configuration 0 is used by default if a part set mode is not selected and this
is used as the 'full' set. The other three set modes are for use as 'part' sets.
These configurations will have been pre-programmed by your Engineer.
Entry / Exit Mode
1) Entry:
When the panel is set and an Entry / Exit zone is triggered the Entry / Exit timer will
begin to count down.
During this period an Entry / Exit tone (single repeated bleep) will be produced by the
internal sounder and any zones which are programmed as Access zones will be
ignored.
If either the limited user code or the master code are entered before the end of the
count down period the panel will return to day mode.
If the timer is allowed to elapse before a user code is entered the panel will go into an
alarm state.
In this case the system needs to be 'Unset' (See 'Unsetting The Panel' below).
2) Exit:
With the panel in 'day' mode, if either a user code or an Easy-set key sequence is
entered the Entry / Exit timer will begin.
If all the immediate zones are clear, then the Entry / Exit tone will be heard. Leave the
protected area by the predetermined Entry / Exit route.
As you trigger Access zones the tone will change temporarily to a repeated low tone.
When all the zones are clear, the Entry / Exit tone will continue again until the end of
the time-out period. The panel will then be set.
MASTER USER FUNCTIONS
The Master User has access to all the Limited User functions plus the following:
1. Clear Event Log.
Enter (If allowed by Engineer)
2. Change Limited User Code.
Enter < < <
Master User Code New Limited User Code New Limited User Code
3. Change Master code.
Enter < < <
Master User Code New Master User Code New Master User Code
4. Test mode.
Enter < All LEDs are switched on except the fault LED and
backlight LED.
< The strobe is switched on.
< The bell is switched on.
< The internal sounder is switched on.
5. Clear flashing alarm LED.
Enter or
Master User Code Limited User Code
6. Walk test Then set the panel in the normal way.
Unset the panel to exit walk-test mode.