EasyManuals Logo
Home>Quick>Soldering Gun>3202

Quick 3202 User Manual

Quick 3202
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
. Safety Instruction
WARNING
In this instruction manual, WarningCaution and Note are defined as
followings:
WARNING: Misuse may potentially cause death or serious injury to the
user.
CAUTION: Misuse may potentially cause injury to the user or physical
damage to the objects involved. For your own safety, be sure
to comply with these precautions.
CAUTION
When the power is on, the tip temperature is very high. Follow the
precautions strictly as mishandling may cause burn or fire:
Do not use the unit for other applications.
Do not touch the metallic parts near the tip.
Do not use the product near flammable items.
Inform other people in working area that the temperature of this unit
could be very high during the work. Power the unit off when the work is
finished to avoid danger.
Power off the unit and wait till the temperature cools down to room
temperature when replace or install the parts.
To prevent damage to the unit and ensure a safe working environment,
be sure to comply with the following precautions:
Only use this unit with rated voltage and frequency (refer to the
trademark back of equipment).
If there’s any damage to the unit, stop using it.
1. Pull out the iron tip by the needle at the soldering handle holder. the iron tip
and the iron tip
encloser are in together.
2. Pull out the heating element towards the iron tip of the iron handle.
3. Push the handle cord12lightly forwards and pull the PCB for line
connectionand handle cord out of the iron handle (towards the tip of the
handle).
NOTE:
Do not use metal tools such as pliers to remove tip or Tip encloser from
the iron handle.
10.3 Measure the Resistance before Replacing
NOTE:
Measure the resistance when the heating element is at room temperature.
1. Resistance value of heating element is 4Ω.
2.
If the resistance value is not normal, replace the heating element. Refer to the
instructions included with the replacement part.
10.4 Measure the Resistance after Replacing
After replacing the heating element:
1. Measure the resistance values “a” and “b” to confirm that the leads are not
twisted and that the grounding wire is properly connected.
2. The pins of the handle plug are as followings:
Pin1: Blue Pin2: Red
Pin3: Green Pin4: Metal layer of shielding cord
Pin5: White of shielding cord Pin6: White