68
15. COOPERATION WITH PRINTER OR COMPUTER
Every pressing of key < PRINT > sends signal of current display state with
measuring units to computer or printer. Balance has factory setting speed of
transmission 4800 bit/s. If external mechanism (printer, computer) require digferent
setting of speed of transmission, change factory setting on speed in menu
(parameter bod)
Transmission parameters programmed in balance:
- Speed of transmission - 2400 – 19200 bit / s
- Data bits - 8
- Stop bit - 1
- Parity control - none.
Sending weighing results to computer can take place:
- manually - after pressing PRINT key
- continuously – after function activating or sending steering commend
- automatically – when result is stable (if REPL YES and before
placing weighed load balance indicated value below set Lo value)
- on demand computer – see List of messages
Value indicated by display can be sent through connection in series as:
- stable – start of sending the information will take place when weighing
result is stable
- unstable – state of display is sent to external device when pressing
PRINT key, and on printout such state is marked with <?> before
weighing result.