Re S.p.A. WG251 SKB-B RESMART
Rev. 05/15 22/25
Range: 0÷255
Default value: 0
F.91 - Reset MWG10
This function resets all the adjustment parameters of the MWG10 device to the default values. It also
cancels the custom calibration of the device.
F.92 - Diagnostics
The function is read only one and shows the system values.
SENS 1 value in Volt of sensor 1 (pin 18)
SENS 2 value in Volt of sensor 2 (pin 22)
REED 0 status of proximity: 1=open, 0=closed (pin 13)
REED 1 status of proximity: 1=open, 0=closed (pin 14)
T processor temperature in centigrade
F.99 - Firmware version
The function is read only one and shows the firmware version of the MWG10 device.
Access the F.91 function:
Keep the enter key pressed for a few seconds to access the functions menu window.
Scroll the functions with the + key to reach the F.91.
Press the write key to access the F.91 function and start the reset procedure.
Press the + and – keys at the same time.
The reset is performed and it goes back to the operating window.