22 | Specifications
4 SPECIFICATIONS
OUTPUT CHARACTERISTICS
Inverter Output Voltage
240 V (default)/230 VAC± 3%
(selected by DIP switch S2 or RS232)
Frequency 50 Hz± 0.3 Hz
Output Waveform Pure Sine Wave (THD ≤ 3% @ Full Load & >12.5/25 VDC)
PROTECTION
Battery Input Over / Under voltage protection, Input reverse protection by Fuse
Inverter Output
Short-circuit (< 3s shutdown) protection, Overload protection, Over
current protection by RCBO, Residual current protection (> 30 mA)
by RCBO
Over Temperature Internal heatsink temperature 70°C ± 5°C (158°F ± 9°F)
Over Temperature Recovery Internal heatsink temperature 50°C ± 5°C (122°F ± 9°F)
SIGNAL AND CONTROL
Remote Controller Panel Input REMOTE-RS (optional)
Remote Control Terminal Inverter ON/OFF and Fault Indication
Led Indicator Blue LED
ENVIRONMENTAL
Operating Temperature –20 ~ +40°C (–4 ~ +104°F) (Derates up to 60°C (140°F))
Storage Temperature –30 ~ +70°C (–22 ~ +158°F)
Storage Temp. & Humidity 10~95% RH
Operating Altitude 3 km (1.9 mi)
SAFETY AND EMC
ATS Relay Standards IEC 61810-1
Safety Standards AS/NZS 4763
EMC Standards UN ECE R10
Cooling Temperature and Load Controlled Cooling Fan