TM049 27L Continuous Flow Service Instructions
REV AL – Issued April 2019
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed “uncontrolled”.
DIAGNOSTIC TEST POINTS (cont)
THERMISTOR RESISTANCE CHART
FAULT FINDING
When measuring resistance of a part, turn off the electric power and be sure to
disconnect the part completely before measuring (from connector or terminal).
Resistance checks are performed on the part while it is disconnected from the
control board.
“Live” testing to be conducted. Personal Protective Clothing (PPE) shall
be worn to reduce the risk of electric shock. Refer to Rheem Safety
Procedure on electrical testing.
All Molex connections only go to one location and fit one way. You do not need
to force a connection.
CAUTION: When performing maintenance and/or servicing the water
heater, wait for the water heater to become cool. Be careful to avoid injury
on the sharp edges.