12.0 WIRING DIAGRAM
Wiring Diagram
MATERIAL:
PRINTING INSTRUCTIONS:
NO REVISION TO DESIGN, MATERIAL, TOOLING, OR PROCESS IS ACCEPTABLE
WITHOUT PRIOR APPROVAL FROM RHEEM THROUGH AN AUTHORIZED CHANGE
NOTICE, A REVISED ENGINEERING SPECIFICATION AND A RESAMPLING OF
PARTS. THE SUPPLIER IS RESPONSIBLE FOR NOTIFYING RHEEM R & D AND
PURCHASING DEPARTMENTS IN WRITING OF ANY CHANGES AFFECTING
PRODUCT QUALITY, PERFORMANCE, RELIABILITY, PACKAGING, DELIVERY OR
WORKMANSHIP. “ANY DOCUMENTS REFERRED TO ON THIS DRAWING ARE
INCLUDED IN THE SPECIFICATIONS FOR THIS COMPONENT”.
MAKE EXACTLY
12.0 IN X 4.125 IN. WHITE BACKGROUND
WITH BLACK PRINTING
ADS-4574-02, PRESSURE
SENSITIVE, ADHESIVE BACKED VINYL
WIRE COLOR CODE
BK......BLACK
BR......BROWN
BL.......BLUE
G........GREEN
G Y ......GRAY
O........ORANGE
PR......PURPLE
R........RED
W .......WHITE
Y........YELLOW
ORIGINAL RELEASE
NO.:
MODELED
BY:
CHECKED:APPROVED:
REV:PART NO.:
DATE:
WIRING INFORMATION
WARNING
-CABINET MUST BE PERMANENTLY GROUNDED
AND CONFORM TO I.E.C., N.E.C., C.E.C.,
NATIONAL WIRING REGULATIONS, AND LOCAL
CODES AS APPLICABLE.
REPLACEMENT WIRE
-MUST BE THE SAME SIZE AND TYPE
OF INSULATION AS ORIGINAL (105C. MIN.)
-FIELD INSTALLED
-FACTORY STANDARD
LOW VOLTAGE
-FIELD INSTALLED
-FACTORY OPTION
-FACTORY STANDARD
LINE VOLTAGE
ELECTRICAL WIRING
DIAGRAM
90-101229-33
03
CC.................COMPRESSOR CONTACTOR
CCH...............CRANK CASE HEATER
CHC...............C C H THERMISTOR
COM...............COMMON CONNECTION
COMP.............COMPRESSOR
EVAP...............COIL TEMP
EXV (5 PIN)....ELEC. TX VALVE
EXV (2 PIN)....ELEC. TX THERMISTOR
FAN................OUTDOOR FAN CONNECTION
GND...............GROUND
HGBEXV.......... - - FOR FUTURE USE - -
HIGH...............HIGH STAGE CONNECTION
HPC................HIGH PRESS. CONT.
L1CT...............RUN CURRENT SENS. TRANS.
L2CT...............START CURRENT SENS. TRANS.
LPC.................LOW PRESSURE CONTROL
LPT.................. - - FOR FUTURE USE - -
COMPONENT CODES
CONNECTORS SUITABLE FOR USE WITH COPPER CONDUCTORS
ONLY.
COMPRESSOR MOTOR THERMALLY PROTECTED.
CONNECT FIELD WIRING IN GROUNDED RAINTIGHT CONDUIT TO
FUSED DISCONNECT, VOLTAGE, HERTZ AND PHASE PER RATING,
AND PER NATIONAL AND LOCAL CODES.
LOW VOLTAGE CIRCUIT TO BE N.E.C. CLASS 2 WITH A CLASS 2
TRANSFORMAER 24 VOLT, 50 OR 60 HZ. MIN 18 AWG.
TO THERMOSTAT, REFER TO SYSTEM SCHEMATICS OR
SCHEMATICS ON INDOOR SECTION FOR LOW VOLTAGE
CONTROL WIRING.
UP, SELECT, AND DOWN, PUSH BUTTONS USED FOR TEST AND
DIAGNOSTIC RECALL , SEE PUSH BUTTON LABEL FOR DETAILS.
DUAL 7-SEGMENT LED DISPLAY TO DISPLAY DIAGNOSTIC CODES,
SEE DIAGNOSTIC LABEL FOR DETAILS.
SOLID ON INDICATES Y1 CALL PRESET AT ICC CONTROL
LPC AND HPC ARE AUTOMATIC RESETSWITCHES.
1.....
.
2.....
3....
4.....
......
5.....
.......
.
6.....
......
7.....
......
8....
9....
NOTES
90-101229-33 03
JHB 10-11-14
A-1080S052
OAT.................OUTDOOR AIR TEMP.
OFM................OUTDOOR FAN MOTOR
OLT.................. - - FOR FUTURE USE - -
OST.................SUCTION TEMP CONN.
P11..................RJ 14 COM TAP
PSC................. PSC MTR, CONN.
RBS................. - - FOR FUTURE USE - -
RC...................RUN CAPACITOR
RVS.................REVERSING VALVE CONN.
SC..................START CAPACITOR
SPT.................JUNCTION PRESS. TRANS CONN.
SR...................START RELAY
................WIRE NUT
24 VAC............24 VAC INPUT
REV:PART NO.:
A-1080S126
6-1-2015
02
REVISED TITLE BLOCK. WIRE FROM CC/L3 TO 240VAC WAS BK NOW O, WIRE CC/L1 TO
240VAC WAS O NOW BK.
JHB
ADDED (Y) TO CC COIL TO CC (BOARD), ADDED (BK) TO CC COIL TO CC (BOARD).
A-1080S065
12-15-14
01
JHB
WIRING DIAGRAM
BK
BR
O
PR
O
Y
PR
R
R
BK
BK
BK
BK
R
R
O
O
BR
Y/PK
O/WH
R
Y
Y/BL
BL
WH/BL
BL/WH
BR/WH
BR
Y
L3 IN
L1 IN
BR
BK
L2CT
L1CT
OFM
COMP
c
s
R
LPC
HPC
SC
L3
T1
T3
CC
L1
coil
coil
1
5
SR
2
CHC
CCH
HERM
COM
FAN
CR
Wire Nuts
In Comp Box
OAT
HPC
LPC
RBS
RVS
CC
24VAC
GND
PSC
240VAC
MODBUS
E2
E1
C
R
Y1
Y2
B
W
UTIL24
UTIL
EXV
OAT
OST
OLT
SPT
LPT
HIGH
HGBEXV
P11 EcoNet
Diagnostic Display
UP
Down
Select
Memory Card
Is
R C
Ir
COM
XMIT
MOD XMT
SCHEMATIC DIAGRAM
COMP
c
s
R
OFM
L1
T1
CC
L3
T3
CC
CCH
CHC
SR
5
2
1
SR
SC
R1
RC
HPC
LPC
RBS
RVS
CC
24VAC
GND
PSC
240VAC
MODBUS
E2
E1
C
R
Y2
B
W
UTIL24
UTIL
EXV
OAT
OST
OLT
SPT
LPT
HIGH
HGBEXV
EcoNet
P11
DiagnosticDisplay
Up
Down
Select
MemoryCard
L2
L1
CC
GND
GL
GND
TO
L3
TO
L1
Y1
BR
Y/PK
O/WH
R
Y
Y/BL
BL
WH/BL
BL/WH
BR/WH
CONTROL BOX
EVAP IN
R C
EVAP IN
Y
BK
2 STAGE ECO NET
DEFORST CONTROL
(AC ONLY)
W/ PSC OUTDOOR FAN MOTOR
THE DOTTED BOX NEAR THE DRAWING NUMBER
REPRESENTS A .25 X.25 2D DATA MATRIX.
SEE ADS-104669-01 FOR DATA MATRIX SPECS.
NOTE:
Y-0546S075
9-16-15
03
ADDED DOTTED BOX TO REPRESENT 2D DATAMATRIX AND NOTE
JHB
12.2: 3 Ton Models - PSC Fan Motor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem A17 Series and is the answer not in the manual?

Rheem A17 Series Specifications

General IconGeneral
BrandRheem
ModelA17 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals