HOW TO REMOVE COMPONENTS
3.12 BLOWER
1. Remove fan control wiring harness from control
board (Connector “D”) and wire holder from the
bracket.
2. Remove solenoid valve wiring connecting to gas
orifice block.
3. Remove heat exchanger bracket located top of
center on water heater.
4. Remove the gas orifice block by removing the sev-
en black screws holding it in place.
NOTE: After removing the gas orifice block,
secure four (4) gaskets in a safe location to
avoid loss.
5. Remove the two screws securing the fan assembly.
6. Remove fan assembly according to the following
graphic.