SC No. Level Error Name/Error Condition/Major Cause/Solution
SC498-00 C
Temperature/humidity Sensor error
Temperature Sensor output error: Out of range between 0.76 V and
2.90 V
Humidity Sensor output error: 2.4 V or more
Unmounted Sensor (Unset connector or broken wire)
Failed Sensor
Turn the main power OFF and then ON.
Check that the connector is set.
Set the sensor.
Replace the Sensor.
Replace the connector.
SC500 (Paper Feed and Fusing)
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC508-00 B
By-pass bottom plate operation error
The signal from the by-pass bottom plate position Sensor has not
changed (that is, the signal has not changed from ON to OFF or vice
versa) for 4 seconds or more after the start of reverse Paper Feed Unit
rotation.
If the error is detected three times in succession, the appropriate SC
number is displayed on the operation panel unit.
By-pass bottom plate Sensor connector disconnected or other error
By-pass bottom plate Sensor feeler stuck or other error
Replace the by-pass bottom plate Sensor feeler.
Check and replace the by-pass bottom plate Sensor connector
connection.
Replace the Paper Feed Motor.
Replace the harness.
Replace the BCU.
Service Call
125

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP171 and is the answer not in the manual?

Ricoh Aficio MP171 Specifications

General IconGeneral
BrandRicoh
ModelAficio MP171
CategoryCopier
LanguageEnglish

Related product manuals