SC Code Descriptions
SM 6-32 D245/D246/D247
6.2.6 SC6XX: DEVICE COMMUNICATION
SC No. Level Error Name/Error Condition/Major Cause/Solution
622-00 B 2nd tray communication error
ď‚§ An error occurs during the line connection between the
mainframe and the optional PFU (2nd tray).
ď‚§ A communication error report is received between the
mainframe and the optional PFU (2nd tray) is received.
ď‚§ The 2nd paper tray's main board defective
ď‚§ MPU defective
ď‚§ 2nd tray and the machine are not connected correctly.
ď‚§ Reconnect the 2nd tray connection cable.
ď‚§ Replace MPU.
ď‚§ Replace the 2nd tray.
SC No. Level Error Name/Error Condition/Major Cause/Solution
623-00 B 3rd tray communication error
ď‚§ An error occurs during the line connection between the
mainframe and the optional PFU (3rd tray).
ď‚§ A communication error report is received between the
mainframe and the optional PFU (3rd tray).
ď‚§ 2nd tray main board defective
ď‚§ 3rd tray main board defective
ď‚§ 2nd tray and 3rd tray not connected correctly
ď‚§ Reconnect the 2nd tray and 3rd tray connection cable.
ď‚§ Replace the 3rd tray.