RIGOL Chapter 2 Command System
2-204 MSO1000Z/DS1000Z Programming Guide
:TRIGger:RS232:BAUD
Syntax
:TRIGger:RS232:BAUD <baud_rate>
:TRIGger:RS232:BAUD?
Description
Set or query the baud rate in RS232 trigger. The default unit is bps.
Parameter
Name
Type
Range
Default
<baud_rate>
Discrete
{2400|4800|9600|19200|38400|57600|
115200|230400|460800|921600|1000000|
USER}
9600
Return Format
The query returns an integer or USER.
Example
:TRIGger:RS232:BAUD 4800 /*Set the baud rate to 4800bps*/
:TRIGger:RS232:BAUD? /*The query returns 4800*/
Related
Command
:TRIGger:RS232:BUSer
:TRIGger:RS232:BUSer
Syntax
:TRIGger:RS232:BUSer <user baud>
:TRIGger:RS232:BUSer?
Description
Set or query the user-defined baud rate in RS232 trigger. The default unit is bps.
Parameter
Name
Type
Range
Default
<user baud>
Integer
110 to 20000000
9600
Return Format
The query returns an integer.
Example
:TRIGger:RS232:BUSer 50000 /*Set the user-defined baud rate to 50000bps*/
:TRIGger:RS232:BUSer? /*The query returns 50000*/
Related
Command
:TRIGger:RS232:BAUD

Table of Contents

Other manuals for Rigol MSO1104Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO1104Z and is the answer not in the manual?

Rigol MSO1104Z Specifications

General IconGeneral
BrandRigol
ModelMSO1104Z
CategoryTest Equipment
LanguageEnglish

Related product manuals