Value Series Manual 5
Prepare for installaon
Parts included
Tools needed
Materials needed
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shuto valve during any pressure tesng of the gas
supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa) (13.84 in W.C.).
You must follow the installaon instrucons and
those in Care and Maintenance for adequate
combuson air intake and exhaust.
INFORMATION
If a water heater is installed in a closed water
supply system, such as one having a backow
preventer in the cold water supply line, means
shall be provided to control thermal expansion.
Contact the water supplier or local plumbing
inspector on how to control thermal expansion.
Should overheang occur or the gas supply fail to
shut o, turn o the manual gas control valve to
the appliance.
Keep the air intake locaon free of chemicals such
as chlorine or bleach that produce fumes. These
fumes can damage components and reduce the life
of your appliance.
Tankless water heater
MC-91-2 temperature controller (integrated into
indoor models; provided with outdoor models)
Pipe wrenches (2)
Adjustable pliers
Screwdrivers (2)
Wire cuers
Gloves
Safety glasses
Level
Tools that might be needed
Hammer drill with
concrete bits
Saw
Threading machine with
heads and oiler
Core drill with diamond
head
Torch set
Copper tubing cuer
Steel pipe cuer
Materials that may be needed
Soap soluon
Approved venng
Teon tape
(recommended) or pipe
compound
Pressure relief valve
Heat tape
Pipe insulaon
Electrical wire and
conduit per local code
Concrete wall anchors
Oponal pipe cover
Oponal temperature
controller
5/8” ID PVC exible
tubing
2 conductor 22 AWG
wire for controller
Single gang electrical
box
Wire nuts
Unions, drain valves,
isolaon valves