i-COMM™ CONTROLLER
4 Pub. No. RHSPI388 JANUARY 2006
i-COMM DIGITAL CONTROLLER INSTRUCTIONS
LCD DISPLAY MESSAGES:
TOP DISPLAY BOTTOM DISPLAY REASON ACTION REQUIRED
FAULT MESSAGES
Door Faulted Normal Power Up Indicates Loss of Power Push Open/Reset*
Watchdog Timer Indicates the boards watchdog timer has reset Service Required*
Reset From Sleep Indicates the controller was awaken from sleep mode Service Required*
Low Voltage Drop in voltage caused controller to restart Push Open/Reset*
Breakaway Door is in breakaway mode Reset / Jog Door*
Breakaway Sideframe door (8000CL/XL), Overload Relay (8000/CL/XL) Reset / Jog Door*
Emergency Stop E-Stop pushed, Overload Relay (8900), Inverter (8600) Push Open/Reset*
Open Time Limit Run open time limit exceeded Service Required*
Menu Interrupt Menu Interrupted Push Open/Reset*
Limit Pulse Fail Trakline limit problem (8910/20/PL only) Service Required*
Limit Failure Limit switch has failed Service Required*
Obstruction Door has detected obstruction and reversed 3 times Inspect & Reset*
Unknown Unknown fault Service Required*
System Clock read System clock failed Service Required*
Unknown State State unknown Service Required*
Pro System Pro Inverter Fault Check Inverter*
Jog to Open Pos Displays when jogging open None*
Jog to Close Pos Displays when jogging close None*
* Displays on Screen
DOOR IS OPENING
Door is Opening
DOOR IS OPEN
Door is Open When not in preannounce to close None
Stand Clear When in preannounce to close None
Closing in xx.xs Displays closing time in seconds None
Activation On Indicates activation on (overrides timer display) Device Holding Open
Waiting for cmd. Indicates door is waiting for manual close cmd. Close Door
Photoeye Blocked Photoeye is blocked (overrides timer display) Remove Obstruction
I-Zone Detection I-Zone active (overrides timer display) Remove Detection
DOOR IS CLOSING
Stand Clear Door Closing None
DOOR IS CLOSED
Door Closed Cycles: xxxxxx Displays cycle count None
Door Closed Interlock Active Door is interlocked and cannot be opened Perform Interlocking
DOOR IS STOPPED
Door Stopped Push Open/Close Open/Close Door