3.1) Daily checks
Safety
To warrant reliability and efficiency of the engine, meet and
carefully observe all the operating and maintenance
instructions.
m WARNING
Risk of burnings and scalds! Hot engine parts!
Conduct checks on the cold engine only!
m WARNING
Non-compliance can result in serious injuries or death!
Ignition “OFF” Before moving the propeller switch off both ignition
circuit and secure the aircraft. Have the cockpit occupied by a com-
petent person.
ATTENTION
If established abnormalities (e.g. excessive resistance of the
engine, noise etc.) inspection in accordance with the relevant
Maintenance Manual is necessary. Do not release the engine in-
to service before rectification.
Coolant level
ATTENTION
Operating media are to be observed!
The coolant specifications of the section Chapter 2.3.
Step Procedure
1 Verify coolant level in the expansion tank, replenish as
required up to top. The max. coolant level must be flush
with the bottom of the filler neck.
2 Verify coolant level in the overflow bottle, replenish as
required. The coolant level must be between max. and
min. mark.
ENVIRONMENT NOTE
Protect the environmental!
Never spill any coolant. Dispose of the coolant in an environmentally
sound way!