4.3.3) Exceeding of max. admissible coolant temperature
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Coolant tempera-
ture max.
Applicable for engine S/N with Suffix -01.
Any exceeding of the max. admissible coolant temperature
has to be entered by the pilot into the logbook, stating dura-
tion and extent of over-temperature condition.
Carry out an unscheduled maintenance check according to
Maintenance Manual Line chapter 05-50-00.
4.3.4) Exceeding of max. admissible oil temperature
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Exceeding oil
temperature
Any exceeding of the max. oil temperature must be entered
by the pilot in the logbook, stating duration and extent of
over-temperature condition.
A maintenance inspection should be carried out.
4.4) Oil pressure/Fuel pressure
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Oil pressure
Oil pressure below minimum - during flight
Check oil system.
A maintenance inspection should be carried out.