Effectivity: 912 Serie
Edition 4 / Rev. 0
BRP-Rotax Page 4-5
November 01/2016
4.4.1) Oil pressure below minimum - on ground
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Oil pressure too
low
Immediately stop the engine and check for reason. Check oil
system.
Check oil quantity in oil tank.
Check oil quality. See Chapter: Operating media-Lubricants.
A maintenance inspection should be carried out.
4.4.2) Oil pressure above permitted range at low ambient
temperatures
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Oil pressure
too high
Reduce engine speed and check the oil pressure again once
it has reached a higher oil temperature.
A maintenance inspection should be carried out.
4.5) Engine on fire or fire in the engine compartment
ATTENTION
Carry out emergency procedures as prescribed in the flight man-
ual of the engine manufacturer.
After landing locate the cause of fire and resolve the error be-
fore next flight by qualified staff (authorized by the Aviation
Authorities).
An entry in the logbook must be made.
A maintenance inspection should be carried out.

Table of Contents