Effectivity: 912 Serie
Edition 4 / Rev. 0
BRP-Rotax Page 2-3
November 01/2016
EGT
Exhaust gas temperature
Max. 880 °C (1616 °F)
Conventional
coolant
Applicable for engine S/N without Suffix -01. See also Chapter
2.3.
Coolant temperature: (coolant exit temperature)
Max. 120 °C (248 °F)
Cylinder head temperature:
Max. 150 °C (300 °F)
Permanent monitoring of coolant temperature and cylinder head
temperature is necessary.
Waterless coolant
See also Chapter 2.3
Cylinder head temperature:
Max. 150 °C (300 °F)
Permanent monitoring of cylinder head temperature is necessary.
Conventional
coolant
See also Chapter 2.3
Applicable for engine S/N with Suffix -01.
Coolant temperature limit measured in
the cylinder head
Engine type
Max. 120 °C (248 °F) 912 A/F/UL
Permanent monitoring of coolant temperature is necessary.
Engine start, oper-
ating temperature
Max. 50 °C (120 °F) (ambient temperature)
Min. -25 °C (-13 °F) (oil temperature)