Oil level (oil
dipstick)
NOTE
The oil level should be in the upper half (between the “50%“
and the “max“ mark) and should never falls below the “min.“
mark. Prior to long flights oil should be added so that the oil lev-
el reaches the “max“ mark.
Avoid oil levels exceeding the “max“ mark, since excess oil
could be poured out through the venting system.
Difference between max.- and min.- mark = 0.45 litre (0.95 liq
pt).
ENVIRONMENT NOTE
Protect the environmental.
Observe to bury no oil! Dispose of oil in an environmentally friendly
manner.
3.4) Engine start
m WARNING
Non-compliance can result in serious injuries or death!
Do not start the engine if any person is near the running engine.
Engine start
Step Designation Procedure
1 Fuel valve
open
2 Starting carb activated
IF
engine in operating
temperature
Then
start the engine without
choke.
3 Throttle lever set on idle position
4 Master switch ON
5 Ignition both circuits switched on
ATTENTION
Do not actuate starter button (switch) as long as the engine is
running. Wait until complete stop of engine!
Step Designation Procedure
6 Starter button
actuate
Page 3-6
November 01/2016
BRP-Rotax Effectivity: 912 Serie
Edition 4 / Rev. 0

Table of Contents

Other manuals for Rotax OM-912

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax OM-912 and is the answer not in the manual?

Rotax OM-912 Specifications

General IconGeneral
BrandRotax
ModelOM-912
CategoryEngine
LanguageEnglish

Related product manuals