Connecting the connection cord
t "MXBZTSFNFNCFSUPDPOOFDUUIFSFGSJHFSBOUQJQFTCFGPSFQFSGPSNJOHUIFFMFDUSJDDPOOFDUJPOT
8IFOEJTDPOOFDUJOHUIFTZTUFNBMXBZTEJTDPOOFDUUIFFMFDUSJDDBCMFTCFGPSFEJTDPOOFDUJOHUIFSFGSJHFSBOUQJQFT
t "MXBZTSFNFNCFSUPDPOOFDUUIFBJSDPOEJUJPOFSUPUIFHSPVOEJOHTZTUFNCFGPSFQFSGPSNJOH
the electric connections.
The indoor unit is powered by the outdoor unit by means of a H07 RN-F connection cable (or a more power model),
with insulation in synthetic rubber and jacket in polychloroprene(neoprene), in accordance with the requirements of standard EN 60335-2-40.
1. Remove the screw on the electrical component box and remove the cover plate.
2. Route the connection cord through the side of the indoor unit and connect the cable to terminals; refer to the gure below.
3. Route the other end of the cable to the outdoor unit through the ceiling & the hole on the wall.
4. Reassemble the electrical component box cover, carefully tightening the screw.
Indoor Power supply
Communication Cable
Power Supply .BY.JO7
Indoor Power cable
_7)[ ±10% 1.5mm²Ĺ,3wires _NN¤XJSFT
JPower supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord.
$PEFEFTJHOBUJPO*&$*&$$&/&-&$)3/'PS*&$*&$$&/&-&$)3/'
J4DSFXTPOUFSNJOBMCMPDLNVTUOPUCFVOTDSFXFEXJUIUIFUPSRVFMFTTUIBOLHGtDN
J4JODFJUIBTUIFFYUFSOBMQPXFSTVQQMZSFGFSUPUIFPVUEPPSVOJUJOTUBMMBUJPONBOVBMGPS."*/108&3
Wiring diagram
1 phase
1(L)
2(N) 1 2 V1 V2 F3 F4
F2 F1
1(L) 2(N)
N
L
Indoor Unit
Main power cable
Cable clamp
Communication cable
Cable tie
Between Indoor and Outdoor Connection cable Specications(Common in use)
Terminal Block SPEC (Indoor)
8IFOJOTUBMMJOHUIFJOEPPSVOJUJOBDPNQVUFSSPPN
VTFUIFEPVCMFTIJFMEFE5BQFBMVNJOVNQPMZFTUFS
CSBJEDPQQFSDBCMFPG'30))3UZQF
"$108&3.4$3&8
8.4 9.5
$0..6/*$"5*0/.4$3&8
8.4
9.5
10
10
Indoor Power
In case of extending the electric wire, please
DO NOT use a round-shaped pressing socket.
- Incomplete wire connections can cause
electric shock or a re.
WARNING
Outdoor Unit
L1 L2 L1 L2
L1 L2
Tightening Torque (kgf·cm)
M4 _

Other manuals for Samsung Duct Type Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Samsung Duct Type Series and is the answer not in the manual?

Samsung Duct Type Series Specifications

General IconGeneral
BrandSamsung
ModelDuct Type Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals