Water heat exchange unit
H - 12
lOperate button
lStop button
lCooling/heating change switch
lOperate display LED
lAbnormality display LED
lOil warning display LED
Contact
point
signal
Separately sold remote control or
central monitoring board
Water heat exchanger unit
Hot and cold water
intake temperature
Hot and cold water
outflow temperature
Water heat exchanger b
refrigerant inlet
temperature
Water heat exchanger b
refrigerant outlet
temperature
Water heat exchanger b
freeze prevention
thermostat
Water heat exchanger a
refrigerant inlet
temperature
Water heat exchanger a
refrigerant outlet
temperature
Water heat exchanger a
freeze prevention
thermostat
Key SW 1 No.
Rotary SW 5 No.
4P dip SW 1 No.
5P dip SW 1 No.
8P dip SW 2 No.
Slide SW 4 No.
Water heat exchanger
b-1 electric valve
Water heat exchanger
b-1 electric valve
Water heat exchanger
a-2 electric valve
Water heat exchanger
a-1 electric valve
Controller board
Controller board
Serial communication
20 No. LED output
Oil float switch H level
Oil float switch L level
Bypass valve
Expansion valve
Liquid valve
Four-way valve
Fuel gas valve 1
Fuel gas valve 2
Crank case heater
Neutralizer heater
Cooling water pump
Inverter
Fan motor 1
Fan motor 2
Engine oil supply pump
Solenoid valve 1 for oil supply
Solenoid valve 2 for oil supply
Fuel adjustment valve
Crank angle sensor
Cam angle sensor
Engine oil pressure SW
Cooling water
Starter motor
Ignition 1
Ignition 2
Ignition 3
Ignition 4
Step motor
Engine
PC
LED output 7 No.
7 segment LED
output 6 No.
Key SW 4 No.
Slide SW 2 No.
<sensor input>
Compressor inlet
temperature
Compressor outlet
temperature
Coil inlet tem
perature
Coil outlet
temperature
External air
temperature
Exhaust gas
temperature
Compressor
inlet pressure
Compressor
outlet pressure
Cooling water
float SW
Refrigerant
pressure SW
Interlock
Hot and cold
water pump
operate command
Ancillary equipment control board
Hot and cold water pump power circuit
Flow switch and interlock
5. Control
(1) System block diagram