50
Uporaba termostata v načinu z zunanjim tipalom – talno ogrevanje
The thermostat can be used in several applications. One of them is also for underfloor heating control.
A sensor is not available in the kit, but is available as an accessory to order (NTC 100K). The use of
NTC10K is also an option. The sensor to be used must be precisely selected in the thermostat settings
- ie NTC10K or NTC100K.
In order for the thermostat to use the floor temperature, you must connect a sensor, in thermostat
settings under 5N select the type of your sensor. Then set the temperature control mode in the
settings under the ct setting. Selecting the 5-r value is controlled only by the internal sensor; 5-
F is the use of an internal sensor and an external sensor; r-F is to use only an external sensor.
If you select the 5-r option, then set the desired room temperature by setting the desired
temperature. The sensor used for this function is an internal sensor only.
If you select the 5-F option, then set the desired room temperature by setting the desired
temperature. The sensor used for this function is an internal sensor that monitors the air temperature
and the thermostat is regulated accordingly. With this option, you must have an external sensor
connected, the function of which is to limit the floor temperature or the highest temperature that can
be reached on the sensor. Set the limit in the thermostat settings under the Ct function (see Advanced
thermostat setting).
If you select the r-F option, then by setting the desired temperature you set the desired temperature
that reads from the external sensor (in most cases in the floor).