Appendix: Technical data
The local power supply must be constructed according to IEC 364. To improve safety, the coffee
machine should be tted with an FI 30 mA earth leakage current circuit breaker complying with
EN 61008. Near the device or about 30 cm below the counter top there should be a shockproof socket
as a single-phase connection installed locally on the rear or side wall of the counter substructure or
a country-specic single-phase socket. If the mains connection lead for this device is damaged then
it must be replaced by our customer service personnel or a similarly qualied person. If the coffee
machine is permanently connected to the mains then an all-pole disconnecting separator (mains
switch) according to EN 60947 with a minimum 3 mm contact gap must be installed. A separator
switch is recommended for a exible connection. The mains cable must not come into contact with hot
surfaces. The mains switch and plug top are part of the customer‘s on-site installation. The machine
may not be tted with a xed permanent mains connection if installed on a transporting trolley (a mobile
station).
In order to avoid possible faults from arising on our screened data lines due to potential equalization
currents between the devices, an additional potential equalization unit should be planned for devices
connected to the vending system. (See EN 60309)