Burns:
Touching the exhaust - Allow the unit to cool
Fire - explosion:
Petrol is inammable - Smoking is prohibit-
ed when refuelling and working
Warning! This electric tool generates an
electromagnetic eld during operation. This
eld can impair active or passive medical
implants under certain conditions. In order
to prevent the risk of serious or deadly inju-
ries, we recommend that persons with med-
ical implants consult with their physician
and the manufacturer of the medical implant
prior to operating the electric tool.
6. Technical data
IP class IP23M
Continous power P
nenn
(S1)
2500 W
Maximum power P
max
(S2 5 min)
2800 W
Rated voltage U
nenn
2 x 230 V~
12 V / 10A
Rated current I
nenn
16 A
Frequency F
nenn
50 Hz
Drive engine design 4 stroke 1 cyl-
inder air colled
Displacement 196 cm
3
Maximum power (motor) 4,8 kW / 6,5
HP
Fuel unleaded fuel
Tank capacity 15 l
Type of motor oil 10W30 /
15W40
Amount of oil (approx.) 0,6 l
Consumption at full load 330 g/kWh
Weight 43 kg
Performance class G2
Temperature max 40
°
C
Max. altitude 1000 m
Starter motor
reversing
starter
Spark plug F6RTC
• in the event of damage to the sockets
Regularly check the fuel system for leak-
ages and traces of wear and tear such as
abraded or porous lines, loose or missing
brackets and damage to the tank or tank
lid. All faults must be resolved before use.
The generator should be used, maintained
and refuelled only under the following con-
ditions:
• Sucient ventilation. Avoid environments
in which fumes can accumulate, such as
ditches, basements, excavations and bilg-
es. Observe the air ow and temperature.
The ambient temperature should not ex-
ceed 40°C.
• In closed rooms, disperse hazardous
fumes via pipes. The motor fumes con-
tain carbon monoxide, a toxic, odourless
and colourless gas, which causes severe
health damage and possibly death, when
inhaled.
• Refuel the generator only when there is
sucient lighting. Avoid spilling fuel. Nev-
er refuel the generator during operation.
Leave the motor to cool down for about
two minutes before refuelling.
• Do not carry out refuelling close to open
res, indicator lights or sparking electrical
devices such as power tools, welding ma-
chines or grinding machines.
• Check sound absorbers and air lters for
awless condition. These parts act as
ame protection in the event of misre.
• Do not smoke close to the generator. Do
not wear loose clothing, jewellery or sim-
ilar objects that may get caught by the
starter motor or other rotary parts.
Dangers and protective measures
Exhaust gases:
Inhalation of exhaust gases
Only use the unit outdoors
Electric shock:
Touching the spark plug - Do not touch the
spark plug connectors when the engine is
running