3.15 Troubleshooting: Lost Password
If the administration and/or user password is lost, and there is no DLS available, new passwords
must be provided. For this purpose, a factory reset is necessary. Take the following steps to
initiate a factory reset:
1. On the phone, press the v key to activate the administration menu (the v key toggles be-
tween the user’s configuration menu and the administration menu).
2. Press the number keys 2-8-9 simultaneously. The factory reset menu opens.
3. In the input field, enter the special password for factory reset: "124816".
4. Confirm by pressing i.