Upkeep and maintenance
5.2 Restoring the factory settings
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
31
Restoring the factory settings
Note
When you reset the device parameters, all previously changed settings are lost.
When pressing the button, remember the information in the section "RESET button
(Page 16)".
Follow the steps below to reset the device parameters to the factory settings with the
"RESET" button:
1. Turn off the power to the device.
2. Press the "RESET" button for example with a screwdriver and reconnect the power to the
device while holding down the button.
3. Hold down the button until the red error LED "F" stops flashing after approximately 20
seconds and is permanently lit.
4. Release the button and wait until the fault LED "F" goes off.
The device starts automatically with the factory settings.
Follow the steps below to reset the device parameters to the factory settings with the PST:
1. Select the device whose parameters you want to reset.
2. Click on the menu item "Reset" in the "Module" tab.
3. Confirm the prompt with "OK".
You will find detailed information on resetting the device parameters using the WBM and CLI
in the configuration manuals (Page 3):
● SCALANCE XB-200 Web Based Management, section "Restart"
● SCALANCE XB-200 Command Line Interface, section "Reset and Defaults"