Technical specifications
6.10 Switching properties
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
49
6.10
Switching properties
The following technical specifications apply to the following devices:
SCALANCE XB208
SCALANCE XB205-3 (SC)
SCALANCE XB205-3LD (SC)
SCALANCE XB205-3
SCALANCE XB216
SCALANCE XB213-3 (SC)
SCALANCE XB213-3LD (SC)
SCALANCE XB213-3
Switching properties
Aging time
Can be configured (default value: 40 seconds)
Max. number of learnable
addresses
8192
Switching technique
Store and forward
Latency
10 microseconds
Full wire speed switching:
Number of frames per second (at 100 Mbps)
Frame length
148810
64 bytes
84459
128 bytes
45290
256 bytes
23496
512 bytes
11973
1024 bytes
9615
1280 bytes
8127
1518 bytes
Note
The number of SCALANCE XB
-200 modules connected in a line influences the frame delay.
When a frame passes through the s
witch, this is delayed by the store-and-
forward function of
the SCALANCE XB
-200 by 10-130 microseconds (at 100 Mbps).