ERPC functions
6.2 ERPC services and communication
CP 343-1 ERPC
Manual, 03/2010, C79000-G8976-C239-02
41
In the CPU, apart from the logical trigger, you can also see the variables that define the
readable/writable data areas in the form of configurable ERPC symbols. No resources
are required on the CPU for read and write jobs from the application.
The "ILS Workbench" for configuring the ERPC application and "STEP 7" for configuring the
SIMATIC station are shown among the configuration tools.
6.2.3 Reading and writing data
Types of read/write jobs
To allow the ERPC application to read or write data, the following options are available:
Reading from the CPU
Cyclic reading from the CPU
Following a read job, data is read cyclically from the CPU by the CP and sent to the
ERP subscriber.
Spontaneous reading from the CPU
Following a single read job from the ERP application, data is read once from the CPU
by the CP and sent to the ERP subscriber.
Writing to the CPU
Spontaneous writing to the CPU
The data from the ERP subscriber is written to the CPU once a following a write job.
If data is requested from a logical trigger by the ERP subscriber, this is written to the
CPU using a write job.
Sequence of read and write jobs
If it is problem free, a read/write job from the ERP application is executed in the following
steps:
1. The ERPC application initiates a cyclic read/write job.
For test purposes, the ERPC application on the CP can also accept a spontaneous
read/write job from the ILS Workbench.
2. The CP starts the read/write service with which the values are written to the CPU or read
from the CPU and sent to the CP.
Depending on the size of the data, one or more read/write jobs are sent. With a read task
for which more than one read job is necessary, the CP waits until the last read job is
completed.
3. Once the read jobs have been completed and the data of the read task is complete, the
ERPC application sends the requested data frame to the ERP subscriber.
4. If the ERP subscriber is unreachable, the data frame is stored on the CP.
If an error occurs, and error identified is returned and a diagnostic message is entered in the
diagnostic buffer of the CP.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET CP 343-1 ERPC and is the answer not in the manual?

Siemens SIMATIC NET CP 343-1 ERPC Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET CP 343-1 ERPC
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals