Contact Assignment
L1+ 24 VDC
M1 Ground
M2 Ground
L2+ 24 VDC
5.4 Signaling contact
Information on the signaling contact
The signaling contact is a floating switch that signals error statuses by opening the contact.
The signaling contact must be operated within the range of the operating voltage.
If an error/fault occurs, the signaling contact opens. In normal operation, the signaling
contact is closed.
The signaling contact is connected using a 2-pin plug-in terminal block (spring-loaded
terminal). The terminal block ships with the device and can also be ordered as a spare part.
Note the wiring rules.
NOTICE
Damage due to voltage being too high
The signaling contact can be subjected to a maximum load of 100 mA (safety extra‑low
voltage SELV, 24 VDC).
Higher voltages or currents can damage the device.
Position and assignment
)
)
Figure 5-2 Position of the signaling contact based, for example on the SCALANCE XC-200 with 8
ports and assignment of the terminal block
Connecting up
5.4 Signaling contact
SCALANCE XC-200
Operating Instructions, 12/2017, C79000-G8976-C442-03 53

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE XC206-2 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE XC206-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE XC206-2
CategorySwitch
LanguageEnglish

Related product manuals