Technical specifications
Signaling contact
1)
Quantity 1
Design Terminal block, 2 terminals
Permitted voltage range 24 VDC
Load capability max. 100 mA
Permitted ambient conditions
Ambient temperature During operation up to 2000 m -40 °C to +70 °C
During storage -40 ℃ to +85 ℃
During transportation -40 ℃ to +85 ℃
Relative humidity During operation at 25 ℃ ≤ 95 % no condensation
Housing, dimensions and weight
Design compact
Housing material Basic housing Die cast aluminum, powder coated
Front cover Polycarbonate (PC-GF10)
Degree of protection IP20
Dimensions (W x H x D) 60 x 145 x 125 mm
Weight 540 g
Installation options
● Wall mounting
● Installation on a DIN rail
● Mounting on an S7-300 standard rail
● Mounting on an S7-1500 standard rail
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 46 years
1)
Note the wiring rules (Page 51).
7.2 Technical specifications SCALANCE XC206-2 (SC)
The following technical specifications apply to the SCALANCE XC206-2 (SC).
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors Quantity 6
Connector RJ-45 jack
Properties Half/full duplex, MDI‑X pinning
Transmission speed 10 / 100 Mbps
Technical specifications
7.2 Technical specifications SCALANCE XC206-2 (SC)
SCALANCE XC-200