Available protocols
The following list provides you with an overview of the open protocol ports.
The table includes the following columns:
Protocol
Port
Default port status
Open
The factory setting of the port is "Open".
Closed
The factory setting of the port is "Closed".
Con󹪝gurable port
The port status can be changed.
--
The port status cannot be changed.
Authentication
Speci󹪝es whether the communication partner is authenticated.
Encryption
Speci󹪝es whether or not the transfer is encrypted.
Protocol Protocol/
Port number
Default port status Con󹪝gurable port Authentication Encryption
DHCPv4 Server UDP/67
Closed No No
DHCPv4 Client UDP/68 Open No No
DHCPv6 IPv6 UDP/546 Closed No No
Discard TCP/9 Open, 󹪝ltered -- No No
Echo IP UPD/TCP/9 Open -- No No
EtherNet/IP TCP/44818
UDP/2222
UDP/44818
Closed No No
HTTP TCP/80 Open Yes No
HTTPS TCP/443 Open Yes Yes
Kerberos TCP/464 Open, 󹪝ltered -- No No
MSDP TCP/639 Closed No No
NTP
SNTP
UDP/123 Closed No No
NTP (secure) UDP/123 Closed Yes No
PROFINET UDP/34964,
UDP/49151
… 49159
1)
Open No No
Recommendations on network security
SCALANCE XM-400
16 Operating Instructions, 03/2021, C79000-G8976-C306-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE XM-400 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE XM-400 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE XM-400 Series
CategorySwitch
LanguageEnglish

Related product manuals