8.3 Technical speci󹪝cations of the SCALANCE XM416-4C
The following technical speci󹪝cations apply to the SCALANCE XM416-4C.
Technical speci󹪝cations
Attachment to Industrial Ethernet
Electrical connectors Quantity 12
Connector RJ45 jack
Transmission speed 10 / 100 / 1000 Mbps
Combo ports Quantity 4
Electrical connectors Quantity 4
Connector RJ45 jack
Transmission speed 10 / 100 / 1000 Mbps
Slots for pluggable
transceivers
Quantity 4
Connector SFP transceivers (LC port)
Transmission speed 100 / 1000 Mbps
Diagnostics interface
Serial interface
Quantity 1
Connector RJ-11 jack
Out-of-band interface Quantity 1
Connector RJ45 jack
Electrical data
Power supply Rated voltage 24 V DC
Voltage range 19.2 V DC - 28.8 V DC
Design Terminal block, 4 terminals
Cable cross-section
Minimum
Maximum
0.75 mm
2
(18 AWG)
2.5 mm
2
(12 AWG)
Properties Implemented redundantly
Fusing 3.15 A / 125 V
Maximum
incl. extender
XM416-4C
16 x RJ-45 with
1000 Mbps
Current consumption at 24 V DC 2 A 0.7 A
E󹪜ective power loss at 24 V DC 48 W 16.8 W
Signaling contact Quantity 1
Design Terminal block, 2 terminals
Permitted voltage range 24 V DC
Load capability max. 100 mA
Permitted ambient conditions
Ambient temperature/
In areas according to UL508 or CSA
C22.2 No.142: Temperature of the
ambient air
During operation up to 2000 m -40 °C to +70 °C
During operation up to 3000 m -40 °C to +65 °C
During storage -40 °C to +85 °C
During transportation -40 °C to +85 °C
Technical speci󹪝cations
8.3 Technical speci󹪝cations of the SCALANCE XM416-4C
SCALANCE XM-400
Operating Instructions, 03/2021, C79000-G8976-C306-10 71

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE XM-400 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE XM-400 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE XM-400 Series
CategorySwitch
LanguageEnglish

Related product manuals