Signaling faults
The signaling of errors by the signaling contact is synchronized with the fault LED "F", see
section ""F" LED (Page 34)".
All errors that the fault LED "F" indicates (freely con󹪝gurable) are also signaled by the
signaling contact.
If an internal fault occurs, the fault LED "F" lights up and the signaling contact opens.
If you connect a communications node to an unmonitored port or disconnect it, this does not
cause an error message.
The signaling contact remains open until one of the following events occurs:
The problem is eliminated.
The current status is entered in the fault mask as the new desired status.
Connecting up
6.4 Signaling contact
SCALANCE XM-400
60 Operating Instructions, 03/2021, C79000-G8976-C306-10