Description
3.3 Installation
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 06/2020, A5E44455710A
29
DANGER
Risk of explosion during operation due to too high surface temperature
This can result in death, serious injury, or material damage.
• Prevent the maximum surface temperature from being exceeded by maintaining the
specified operating conditions.
• Monitor the coil temperature. Use the temperature sensor that is built into the stator
winding for this as specified on the rating plate or extra rating plate.
3.3.10 Marking
For applications in Zone 1 (IEC/EN/GOST 60079-10-1, GB3836.14)
0158
II 2G Ex eb IIC T. Gb
0158
II 2G Ex eb IIB T. Gb
0158
II 2G Ex eb IIA T. Gb
1Ex e IIC T. Gb X
1Ex e IIB T. Gb X
1Ex e IIA T. Gb X
CNEx
Ex e IIC T. Gb
CNEx
Ex e IIB T. Gb
CNEx
Ex e IIA T. Gb
For applications in Zone 2 (IEC/EN/GOST 60079-10-1, GB3836.14)
II 3G Ex ec IIC T. Gc
II 3G Ex ec IIB T. Gc
II 3G Ex ec IIA T. Gc
2Ex nA IIC T. Gc X
2Ex nA IIB T. Gc X
2Ex nA IIA T. Gc X
CNEx
Ex nA IIC T. Gb
CNEx
Ex nA IIB T. Gb
CNEx
Ex nA IIA T. Gb

Table of Contents

Other manuals for Siemens SIMOTICS XP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP Series and is the answer not in the manual?

Siemens SIMOTICS XP Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP Series
CategoryEngine
LanguageEnglish

Related product manuals