1 Alarms 01.02
6FC5598-3AA20-0BP2 © Siemens AG 2002 All Rights Reserved
1-96 SINUMERIK 802S/802C (DG)
1.4 Action List
No./Name Explanation Not allowed if Remedy
1. INIT Carry out INI
phase (the tasks
are initialized
after Power On)
2. RESET
t
RESET
(VDI signal: after
Reset, mode
group reset
('BAG RESET')
or Power On)
3. RESET_INITBLOCK Activate Reset
init blocks
(VDI signal: after
Reset)
4. PROG_END Carry out
RESET, end of
program has
been detected
(NC block with
M30)
5. MODESWITCHTOA-
PROGMODE
Changing from
operating mode
to program mode
MDA or Auto-
matic
(VDI signal:
BAG)
1. the channel is active (program
running, block search, loading of
machine data)
2. the program has already been
started in another program mode.
3. a channel has left the mode group
because of an interrupt.
4. Overstore or Digitalize has been
selected.
Press RESET to abort the
program or stop program (not
during block search or ma-
chine data loading)
Abort program using the
Reset key
Press RESET to abort the
program or wait until interrupt
is completed.
Deselect Overstore, Digitalize
6. MODESWITCHTOSAVE-MODE Automatic
change from an
internal operating
mode to the
externally set
operating mode
(During
TEACH_IN, it is
tried after each
stop to switch
over from the
internal operating
mode
"AUTOMATIC,
MDA" to
TEACH_IN)

Other manuals for Siemens SINUMERIK 802C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802C and is the answer not in the manual?

Siemens SINUMERIK 802C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802C
CategoryControl Systems
LanguageEnglish

Related product manuals