Page #67 background imageLoading...
Page #67 background image
-66-
No. ZK2-OM00201
12. Limitations of Use
Exhaust from Ejector
The exhaust resistance should be as small as possible to obtain the full ejector performance. There should
be no shield around the exhaust slit for silencer exhaust type. When the product is installed, one of the ports
should be open to atmosphere.
For port exhaust type, back pressure may increase depending on the piping size and length. Ensure that the
back pressure does not exceed 0.005 MPa (5 kPa).
In addition, the exhaust port should not be blocked or pressurized.
If the sound absorbing material is clogged, it will cause a reduction in the ejector performance.
Sometimes, if the operating environment contains a lot of particles or mist, the replacement of the filter
element only is not enough to recover vacuum performance as the sound absorbing material may be
clogged. Replace the sound absorbing material. (Regular replacement of the filter element and sound
absorbing material is recommended.)
Exhaust Noise
When vacuum ejector generates vacuum, noise can be heard from the exhaust port when the standard
supply pressure is close to the pressure that generates peak vacuum pressure making vacuum pressure
unstable. If the vacuum pressure range is adequate for adsorption, there should not be a problem. If the noise
causes a problem or affects the setting of the pressure switch, change the supply pressure slightly to avoid
the pressure range of the noise.
Maximum Number of Manifold Stations that Can Operate Simultaneously
Note)
Note) As long as the number of stations operated simultaneously is the value on the table or less, then the manifold is
available up to 10 stations.
Item
ZK207
ZK210
ZK212
ZK215
Air pressure
supply (PV)
port
ø8, ø5/16
Complex exhaust
Supply from one side
8
5
4
3
Supply from both sides
10
7
5
5
Individual port exhaust,
High-noise reduction
silencer exhaust
Supply from one side
8
6
6
3
Supply from both sides
10
9
9
6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks ZK2 Series and is the answer not in the manual?

SMC Networks ZK2 Series Specifications

General IconGeneral
BrandSMC Networks
ModelZK2 Series
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals