-24-
No.PS※※-OMV1001
[F 0] Units selection function
Only the product with Units selection function can be set.
The displayed unit can be changed, and depends on the pressure range.
(Pa/kPa units are available when the product does not have the units selection function).
<Operation>
Press the or button in function selection mode to display [F 0].
Press the button.
Move on to select the display unit.
Press the button to set. Return to function selection mode.
Setting of [F 0] Units selection function completed
Display unit and minimum setting unit
Part Number
Rated value
kPa
Pa
mbar
psi
inHg
mmHg
inH
2
O
mmH
2
O
X576
±500 Pa
0.001
1
(Initial
operation)
0.01
0.001
0.001
0.01
0.01
0.1
X577
±1 kPa
0.001
(Initial
operation)
1
0.01
0.001
0.001
0.01
0.01
0.1
X578
±2 kPa
0.01
(Initial
operation)
2
0.1
0.001
0.001
0.1
0.01
1
X579
±5 kPa
0.01
(Initial
operation)
-
0.1
0.001
0.01
0.1
0.1
1
X580
±10 kPa
0.01
(Initial
operation)
-
0.1
0.01
0.01
0.1
0.1
1
-: No unit for display
Select the Display Unit
Press the or
button to select the display unit.