-33-
No.PS※※-OMV1001
■[F 5] Auto-preset function
When hysteresis mode is selected, the auto-preset function can calculate an optimum pressure value
automatically based on the on-going operation.
<Operation>
Press the or button in function selection mode to display [F 5].
Press the button.
Move on to setting of auto-preset.
Press the button to set. Return to function selection mode.
Setting of [F 5] Auto-preset function completed
Press the
button during measurement mode to set the pressure.
Then press the
button again to change the pressure setting, while the display is flashing.