-59-
No.PS※※-OMV1001
Specification
Set pressure range (Refer to page 61)
Air, inert gases and incombustible gases
12 to 24 VDC ±10%, ripple (p-p) 10% or less
Rough adjustment mode: 0, 0.2, 0.5, 1, 2, 5, 10, 20 s
Fine adjustment mode: 200 to 1000 ms (increments of 5 ms)
: The digital filter set value affects the response of the pressure display,
analogue output and switch output. (See Figure on page 60)
NPN or PNP open collector output: 1 output
NPN or PNP open collector output: 2 outputs
1 V or less (at 80 mA load current)
4 ms or less
(with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms,
10 s, 30 s or 60 s selected)
Output Voltage
(rated pressure
range)
Output current
(rated pressure
range)
Max. load impedance: 300 (at power supply voltage of 12 VDC)
600 (at power supply voltage of 24 VDC)
Min. load impedance: 50
4 digits, 7-segment, dual-colour display (red/green)
±2%F.S. ±1digit (at ambient temperature 25±3 C)
LED is ON when output is ON OUT1: Green OUT2: Red
1: If the applied voltage fluctuates around the set value, the hysteresis must be set to more than the fluctuation width. Otherwise,
chattering will occur.
2: If analogue voltage output is selected, the analogue current output cannot be selected.
3: If analogue current output is selected, the analogue voltage output cannot be selected.