How to start and terminate your work
How to test indicators and audible alarm
You can test the indicators and the audible alarm of the
X-ray unit.
Use the navigator to move to item Diagnosis in the Main menu
and activate this item. The menu illustrated beside is displayed.
Go to item Indicator test and activate it.
Use the navigator to activate the indicators on the key-
board, the radiation indicators and the audible alarm.
After about 1 second the radiation indicators are deac-
tivated again. As soon as you release the navigator the
other indicators and the audible alarm will be deactiv-
ated as well.
How to log out
To protect the operators from overtiredness, newer soft-
ware allows to request the operator to log out after a pre-
defined time. Higher authorization users can activate this
function and set the time interval.
Acknowledge the message and then log out (see below).
Logout via ISIS card*
Just withdraw your ISIS card from the card reader and you have logged out.