d.
Connect the cable wires to the 7-pin connector, as shown below, and reconnect
the connector to the slot:
Figure 10: Communication and 12V cables connection between Backup Interface and
Inverter
3.
Connect the cables to the Backup Interface:
a. Pass the cables through the Com 1 conduit.
b. Remove the 7-pin connector from the Backup Interface's communication slot.
c. Connect the communication cable to the 7-pin connector, as shown above. If
there is a short circuit jumper between the RSD terminals of the inverter, remove
it before connecting the RSD terminals to the Backup Interface.
d. Reconnect the 7-pin connector to the communication slot.
e.
Move up (ON)the communication DIPswitch.
Figure 11: Communication DIP switch setup
To connect to the AC cable
1. Connect one end of the AC cable to the ACterminal block in the inverter's
Connection Unit, as explained in the Single phase energy hub inverter with prism
technology Installation Guide.
Backup Interface Installation Guide MAN-01-00728-1.0
16 Connecting the Backup Interface to the Inverter

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge StorEdge BI-NUSGN-01 and is the answer not in the manual?

SolarEdge StorEdge BI-NUSGN-01 Specifications

General IconGeneral
BrandSolarEdge
ModelStorEdge BI-NUSGN-01
CategoryRecording Equipment
LanguageEnglish

Related product manuals