1-2
DCR-HC30/HC30E
2. POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so
that the unit cannot operate.
This following two methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Use the AC power adaptor.
Method 2.
Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the commander switch to the “ADJ” side.
3. TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1 Remove the cabinet (R) section.
2 Remove the front panel block assembly.
3 Remove the BAT, EVF block assembly.
4 Remove the lens block assembly.
5 Remove the mechanism deck and the VC-351 board.
6 Open the VC-351 board.
7 Disconnect CN9102 (27P, 0.3mm) of VC-351 board.
8 Supply +4.5V from the DC power supply to the loading motor and unload with pressing the cassette compartment.
ENGLISH JAPANESE
ENGLISH JAPANESE
VC-351
CN9102
VC-351 board
DC power supply (+4.5Vdc)
Loading motor
Disconnect the flexible board from
CN9102 of VC-351 board.