1) The portion in lower case letters in the above codes is one of the following
numbers.
pp: Number identifying the corresponding port.
81: Port A
82: Port B
83: Port C
84: Port D
2) Information in parentheses () indicates short messages for display on the
status bar or superimposed display.
Memory status messages
The following warning messages appear depending on the
wear or usage of the memory. Using memory repeatedly
gradually increases the possibility that errors will occur
during recording and playback. When any of the following
messages appear, it is time to replace with new memory.
Specifically, if the “CONDITION x BAD” message
appears, it is best to replace with new memory as soon as
possible.
E10101 MEMORY FULL, NOT RECORDABLE
(M1 FULL)
The recording operation/command was terminated
because there was insufficient remaining recording
capacity in memory.
Deletes files from memory.
E10201 MEMORY COND3 BAD, NOT RECORDABLE
(M1 COND3 BAD)
Cannot record because the swap space to replace bad
memory cells has been consumed in memory. The
recording operation/command was terminated.
E10301 MEMORY FUNCTION LIMIT
(M1 FUNC LIMIT)
The recording/playback operation was terminated due to
memory function limits related to recording and playback.
E10501 MEMORY MAXIMUM FILES, NOT
RECORDABLE
(M1 MAX FILES)
The recording operation/command was terminated
because the number of files in memory has reached the
upper limit.
Deletes files from memory.
E10601 MEMORY FILE SYSTEM STUFFED, NOT
RECORDABLE
(M1 FS STUFFED)
The recording operation/command was terminated
because the memory file system control limits have been
reached.
Format the memory to use it for recording.
E202pp PORT x FULL, STOP RECORDING
(P-x FULL STOP)
Recording was terminated for the indicated port because
the memory is full.
Code
1)
Indication
2)
Description
Code Indication Description
C10101 SLOT Mx CONDITION1 DOUBTFUL
(M1 COND1 DBT)
The number of errors when writing/reading is becoming larger.
Although all errors can be corrected, it is recommended that
you replace with new memory.
C10201 SLOT Mx CONDITION1 BAD
(M1 COND1 BAD)
The number of errors when writing/reading has become
extremely large.
Although all errors can be corrected, it is strongly
recommended that you replace with new memory.
C10301 SLOT Mx CONDITION2 DOUBTFUL
(M1 COND2 DBT)
The number of memory repetitive operations has become
large.
Although there is currently no problem, it is recommended that
you replace with new memory.
C10401 SLOT Mx CONDITION2 BAD
(M1 COND2 BAD)
The number of memory repetitive operations has become
extremely large.
Although there is currently no problem, it is strongly
recommended that you replace with new memory.
C10501 SLOT Mx CONDITION3 DOUBTFUL
(M1 COND3 DBT)
The swap space used to replace bad memory cells is
becoming smaller.
Although there is currently no problem, it is recommended that
you replace with new memory.
C10601 SLOT Mx CONDITION3 BAD
(M1 COND3 BAD)
The swap space used to replace bad memory cells has been
exhausted.
Although playback is still available, recording is no longer
possible.
It is strongly recommended that you replace with new memory.