10
ELECTRICAL REQUIREMENTS
All Synesso machines are rated to operate on 220 VAC / 60 Hz or 230 VAC / 50 Hz frequency, single phase.
Machines will operate between 208 V and 240 V.
Listed amp rangs are all measured at 220 V. Incorrect voltage can cause malfuncon or damage to the ma-
chine. Plug or means of isolaon must be easily accessible.
An electrical socket and matching plug, rated at the proper voltage and amperage are required within three
feet of the machine. Plug ends are NOT included with the machine unless required by CSA or other cerca-
on.
Aach the plug end per manufacturer’s instrucons.
Make sure that the electronics switch and the heang element breaker are in the OFF posion, then plug the
power cord into the receptacle.
OPTIONAL: If recovery me is slow, or voltage is low, you may install an In-Line Buck-Boost transformer.
Buck-boost transformers come in dierent sizes. Please choose the appropriate one for your machine if re-
quired. Machines require a 1.0 KVA transformer.
SPECIAL ELECTRICAL INFORMATION FOR EMC-COMPLIANT MACHINES
(CE FOR EUROPE AND OTHER LOCATIONS)
To comply with EMC (Electromagnec Compability) regulaons, machines built prior to May 2019 included
a capacitor in the electronics box across the main power IN. To avoid an electric shock from the charge held
in the capacitor, unplug or isolate the machine with the electronics ON/OFF red rocker switch in the ON
posion.
North American Wire Color Worldwide Wire Color
Green Ground Green and Yellow Ground (Earth)
White 110 V Line 1 Brown 230 V
Black 110 V Line 2 Blue Neutral
Model Cord Plug Rang (UL Listed) Machine Max Amp Draw Machine Max Was
S200 30 amp 28 amp , 220 V / 60 Hz 5956 Was, 230 V / 50 Hz
S300 40 amp 36 amp , 220 V / 60 Hz 7656 Was, 230 V / 50 Hz