11
INSTALLATION & WORK STATION
To maintain the 2 year warranty, an authorized or cered espresso service representave
must perform the installaon of this espresso machine.
Site Preparaon - See Diagrams pages 12-13. The machine must be placed on a level horizontal surface that
can be easily cleaned and is capable of supporng a minimum of 300 lbs.
The counter top requires a depth of 28”, which provides a minimum clearance of 1” behind and 3” in front
of the machine.
The height of the surface can vary to suit the operator.
Make a 2 ½” minimum diameter hole through the counter top located according to the diagrams on pages
12 and 13. The hoses, drain tube, and electrical lines will all pass through this hole.
A 3/8” min. diameter cold water supply line from the lter with a shut o valve is required within 5’ of the
machine. The valve should be easily accessed for machine service.
The machine supply hose and pump ngs are 3/8” tube compression ngs.
A proper water ltraon or soening system must be installed on the incoming water supply. Water treat-
ment requirements will vary, and it is important to use a system designed to match the needs of your spe-
cic area. Water ltraon systems require periodic maintenance, including cartridge or lter replacement.
Proper ltraon and service is vital to the funcon of the machine and the quality of the espresso served.
Follow the instrucons provided by your water treatment system for proper installaon.
Note: Improper water ltraon can result in severe damage to the machine including scale deposits and cor-
rosion. DAMAGE CAUSED BY IMPROPER WATER TREATMENT WILL NOT BE COVERED BY THE MACHINE
WARRANTY. See page 8.
There must be adequate room under the counter to locate the motor and pump. The pump must be easily
accessible for adjustment, and the motor must have a minimum of 3” clearance on all sides for air ow.
A oor drain or sink must be available. The best locaon is directly under the machine. The 3/4” drain hose
should descend as vercally as possible for opmal drainage. An air gap is required between the end of the
drain hose and the highest water posion of a clogged drain. This is to prevent the possibility of drain water
backing up into the machine.