19
PROGRAMMING
Factory Sengs:
The factory sengs for your machine are as follows:
Brew Group Temperature 203°F
Steam Tank Temperature 250°F
Program Mode Universal (2 programs)
Temperature Units Fahrenheit
Le program: Right program:
Pre-Infusion 4 seconds Pre-Infusion 4 seconds
Total Water Count 280 Total Water Count 380
The set point is a goal temperature for the brew tank. The tank will heat to reach the set point, then use a PID
based algorithm to remain stable and balanced at that temperature when in use.
Allow 10-15 minutes for a brew group to adjust to a large set point change. Smaller changes take less me to
restabilize.
Line 2 indicates the set point for brew group 1, in this example “203.0F”.
Line 3 indicates the set point for brew group 2, in this example “203.0F”.
To cycle to the next display screen, press the down buon.
Menu Level 1: Brew Temperatures