EasyManuals Logo
Home>Taylor>Freezer>C722

Taylor C722 User Manual

Taylor C722
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
1-2
TO THE INSTALLER
Model C722
To the Installer
1
CAUTION! This machine must be installed on
a level surface to avoid the hazard of tipping. Extreme
care should be taken in moving this machine for any
reason. Two or more persons are required to safely move
this machine. Failure to comply may result in personal
injury or damage to the machine.
The authorized installer should inspect the machine for
damage and promptly report any damage to the local
authorized Taylor distributor.
This machine is made using USA sizes of hardware. All
metric conversions are approximate and vary in size.
Water Connections
(Water-Cooled Machines Only)
An adequate cold water supply must be provided with a
hand shutoff valve. On the underside of the base pan or
on the right side, two 3/8 in. IPS water connections for
inlet and outlet are provided for easy hookup.
Permanently connect the machine using 1/2 in. (12.7
mm) inside diameter water lines. (Flexible lines are
recommended, if local codes permit.) Depending on local
water conditions, it may be advisable to install a water
strainer to prevent foreign substances from clogging the
automatic water valve. There will be only one water in
and one water out connection. Do not install a hand
shutoff valve on the water out line! Water should always
flow in this order: First, through the automatic water
valve; second, through the condenser; and third, through
the outlet fitting to an open trap drain.
IMPORTANT! A backflow prevention device is
required on the incoming water connection side. Please
see the applicable national, state, and local codes for
determining the proper configuration. Water pressure to
the unit must not exceed 150 psi (1034 kPa).
Electrical Connections
IMPORTANT! In the United States, this
machine is intended to be installed in accordance with
the National Electrical Code (NEC), ANSI/NFPA 701987.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, the machine should be
installed in accordance with the existing local codes.
Please contact your local authorities if you have any
questions.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
machine for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications.
See the wiring diagram provided inside the electrical box
for proper power connections.
WARNING! This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
WARNING! Avoid injury.
DO NOT operate the machine unless it is
properly grounded.
DO NOT operate the machine with fuses larger
than specified on the machine's data label.
All repairs should be performed by an
authorized Taylor service technician.
The main power supplies to the machine must
be disconnected prior to performing installation,
repairs, or maintenance.
For Cord-Connected Machines: Only Taylor
service technicians or licensed electricians may
install a plug or replacement cord on the
machine.
!
FOLLOW YOUR LOCAL ELECTRICAL CODES.

Other manuals for Taylor C722

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C722 and is the answer not in the manual?

Taylor C722 Specifications

General IconGeneral
BrandTaylor
ModelC722
CategoryFreezer
LanguageEnglish

Related product manuals