Operating Procedures2213A Operators
6. Select the DLYD HORIZONTAL MODE and increase
the sweep speed to magnify the intensified portion of the
sweep (see Figure 4-10).
7. The apparent sweep magnification can be calculated
from the following formula:
Apparent
Delayed Sweep
Magnification
initial SEC/DIV setting
second SEC DIV setting
EXAMPLE: Determine the apparent magnification of a
display with an initial SEC/DIV switch setting of 0.1 ms
per division and the second SEC/DIV switch setting of
1 ixs per division.
Substituting the given values:
Apparent lx104s
Magnification 1 x 106s
102 =100
4-10